B. Braun Vista Basic Large Volume Infusion Pump
The B. Braun Vista Basic Large Volume Infusion Pump (#637-202) is designed to be incredibly simple and easy to use. From set installation, to programming, to special mode use and alarm correction each mode ensures simplicity throughout every phase of the infusion process.
Warranty: 1 Year.
Note: The B. Braun Vista Basic Large Volume Infusion Pump requires a medical license and will ONLY ship to medical facilities within the US.
Featuring robust components, the B. Braun Vista Basic Large Volume Infusion Pump is exceptionally durable and provides high reliability throughout the infusion process. Various modes and features include: pump and set-based free flow protection, straight-line tubing, quick start-up for continuous infusions by entering rate and volume, program mode and ramp/taper mode, and helpful prompts to walk the user through the programming process.
Features
B. Braun Vista Basic Large Volume Infusion Pump Features
- Robust mechanical components ensure exceptional durability.
- Two-year preventive maintenance schedule helps save money versus typical annual inspection requirements.
- Battery lasts approximately 3 years before a replacement is required.
- Sets not made with DEHP to protect patients. Needle-free sets protect both the patient and the clinician.
- Helpful prompts walk the user through the programming process.
- Easy to use, teach, and learn making it ideal for homecare settings.
Specifications
B. Braun Vista Basic Large Volume Infusion Pump Specifications
- Product Code: 637-202.
- NDC Number: 08021-0007-47.
- Reference Number: 637-202.
- Mechanism: Linear peristaltic volumetric infusion pump.
- Dimensions: 5.5 in (14 cm) x 9.4 in (24 cm) x 7.8 in (20 cm).
- Weight: 6.8 lb (3.1 kg).
- Power Requirements: 100 – 120 VAC, 50 – 60 Hz, 12 Watts.
- Leakage Current: Max 30 µA.
- Battery: 7.2 V, 1.2 Ah NiCd (rechargeable).
- Battery Operating Time: ~ 3.5 hours at 12 mL/hr.
- Rate Range: 0.1 to 800.0 mL/hr in 0.1 mL increments with Vista tubing.
- Volume to be Infused Range: 0.1 to 9999.9 mL.
- Occlusion Pressure: Variable Settings –
- Low: 8 PSI.
- High: 17 PSI.
- KVO Rate: 1 mL/hr or selected rate, whichever is lower.
- Flow Rate Accuracy: +/- 5% measurement time 8 hr, temp. 71.6° F.
- Alarms: Air-in-Line, low battery, plug-in-now, bag empty, downstream occlusion, door open, pump stopped, KVO, unit malfunction.
- Air-in-Line Alarm: Air bubble size 0.3 mL* or 1.5 mL/hr.**
- Memory: User option to retain last continuous and piggyback mode data upon power up. Permanent data retention in program and ramp/taper modes after pump is turned off.
- Tubing: B. Braun Vista administration sets.
- Modes/Features: Continuous and piggyback modes, program mode for variable infusions, ramp/taper mode fo TPN infusions and delay a mode for postponing infusion start and finish.
- Operating Temperatures:
- Operating: 64.4° to 95° F, 10.15 PSI to 15.37 PSI.
- Non-Operating: -14° F to 131° F, 10.15 PSI to 15.37 PSI.
- Latex Information: Components DO NOT contain natural rubber.
- Total Shelf Life: 35 months.
- Ordering Unit: ST.
- Sterile: No.
* = Can be set from 0.01 to 0.3 mL in service program.
** = Can be set from 0.5 to 3.5 mL/hr in service program.
Accessories
B. Braun Vista Basic Large Volume Infusion Pump Accessories
The B. Braun Vista Basic Large Volume Infusion Pump is commonly purchased with:
- B. Braun Disposable IBP Transducer (#IP-BB-300).
- B. Braun Infusomat Space Pump (#639-003).
- B. Braun Perfusor Space Pump (#639-002).
Literature
B. Braun Vista Basic Large Volume Infusion Pump Literature
B. Braun Infusion Systems Product Catalog
B. Braun Vista Basic Large Volume Infusion Pump Instructions for Use