CPAC RapidHeat RH-Pro9 HVHA Sterilizer
The CPAC RapidHeat RH-Pro9 HVHA Sterilizer includes three instrument trays, tray removal safety gloves, an instruction and care card, and a user manual.
Warranty: 3 Years – Parts and Labor.
The industry’s most energy-efficient, medium-capacity sterilizer, the RH-Pro9 from CPAC is capable of fitting into most dental cabinets while still featuring three instrument trays to handle all your sterilization needs. Much like the larger RH-Pro11, the RH-Pro9 utilizes advanced HVHA (High-Velocity Hot Air) technology to provide the fastest instrument turnaround of any FDA-Cleared sterilization technology. No steam or water means no corrosion and a longer instrument life. It is simple and intuitive to use thanks to it’s easy to operate touchscreen and you will also enjoy faster-processing and less maintenance and down time.
Features
CPAC RapidHeat RH-Pro9 HVHA Sterilizer Features
- Waterless sterilization with no chemicals.
- Non-corrosive sterilizer environment.
- No steam. No drying. No corrosion. No maintenance.
- Uses 85% less energy than steam.
- More energy-efficient.
- FDA-cleared 6 minute cycles (unwrapped).
- FDA-cleared 12 minute cycles (wrapped).
- Simple and easy touchscreen operation.
- Faster-processing.
- Less maintenance and down time.
- Three large instrument trays.
- Smaller cabinet-ready size (1,163 cubic inches). Fits easily into most dental cabinets.
Specifications
CPAC RapidHeat RH-Pro9 HVHA Sterilizer Specifications
- Unit Size (OD): 19.6″ W x 17.5″ D x 13.3″ H (498 x 445 x 338 mm).
- Chamber Size (ID): 9.5″ W x 15.6″ D x 7.85″ H (241 x 396 x 199 mm).
- Chamber Capacity: 1,163 cubic inches (5 gal/19 liters).
- Weight: 60 lb (27 kg).
- Shipping Weight: 75 lb (34 kg).
- Instrument Tray: 7.3″ W x 12″ D x 0.85″ H.
- Electrical:
- 110-120 V, 60 Hz, 1400 Watts warm up, 300 Watts operating.
- 220-240 V, 50 Hz, 1400 Watts warm up, 200 Watts operating.
- TUV Electrical Safety/EMI.
- CE Directive Compliance.
- Sterilization Temperature: 375° F (190° C).
- Safety: Meets Requirements of U.S. Electrical Safety Standards.
- Sterilization Times:
- Cycle 1: 6 minutes for unwrapped instruments.
- Cycle 2: 8 minutes for hand pieces and medical drills.
- Cycle 3: 12 minutes for wrapped, pouched instruments, trays, and cassettes.
- Low Temperature Sterilization Times:
- 320 degrees F: 36 minute cycle.
- 300 degrees F: 56 minute cycle.
- 280 degrees F: 126 minute cycle.
-
Instrument Capacity:
- Unwrapped: 2.4 kg; 120 Dental Instruments.
- Handpieces (Unwrapped): 15 Handpieces; 5 per Tray.
- Wrapped Instruments: 2 kg; 8 Dental Instruments/Pouch; 4 Pouches/Tray; 3 Trays/Load. Total Instruments/Load: 96.
-
Wrapped Cassettes:
- 5.5″ x 8″ x 1.5″: 3 Cassettes (Total: 24 Instruments).
- 6″ x 8″ x 1.5″: 3 Cassettes (Total: 54 Instruments).
- 8″ x 11″ x 1.5″: No 8″ x 11″ Cassettes.
- N95 FFR Mask Decontamination (175 degrees F): 30 minute cycle.
Voltages
CPAC RapidHeat RH-Pro9 HVHA Sterilizer Voltages
- #RH-Pro9: 110 – 120 V.
- #RH-Pro9-230V: 220 – 240 V.
Literature
CPAC RapidHeat RH-Pro9 HVHA Sterilizer Literature
CPAC RapidHeat RH-Pro9 HVHA Sterilizer Cassette Wrapping and Taping Instructions
CPAC RapidHeat RH-Pro9 HVHA Sterilizer Specifications Sheet
CPAC RapidHeat RH-Pro11/RH-Pro9 HVHA Sterilizers Brochure